AXIS#.SM.V2

Description

AXIS#.SM.V2 defines the velocity that is used in service motion modes 1 and 2 (AXIS#.SM.MODE) in the closed velocity and position mode of operation.

Versions

Action Version Notes
Implemented 02-00-00-000

General Information

Type

Read/Write

Units

Rotary: RPM, RPS, deg/s, (custom units)/s, rad/s

See Velocity Units for details.

Range

Depends on units. See Velocity Range for details.

Default Value

60 rpm/1 rps

Depends on units. See Velocity Units for details.

Data Type

Float

See Also

Service Motion, AXIS#.SM.V1

Stored in Non-Volatile Memory

Yes

Variants Supported

All variants are supported.

Fieldbus Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.SM.V1

500eh

06h

Signed32

Velocity

-

Read/Write

No

AXIS1.SM.V2

500eh

07h

Signed32

Velocity

-

Read/Write

No

AXIS2.SM.V1

510eh

06h

Signed32

Velocity

-

Read/Write

No

AXIS2.SM.V2

510eh

07h

Signed32

Velocity

-

Read/Write

No

EtherNet/IP

Name

ID

Hex

Data Type

Access

Units

AXIS1.SM.V1

6406

1906

Signed32

Read/Write

Velocity

AXIS2.SM.V1

71942

1190

Signed32

Read/Write

Velocity

AXIS1.SM.V2

6407

1907

Signed32

Read/Write

Velocity

AXIS2.SM.V2

71943

1190

Signed32

Read/Write

Velocity

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS#.SM.V1

6406

Float

Read/Write

Velocity

AXIS#.SM.V2

6407

Float

Read/Write

Velocity